CUSTOMER:
Expansion
Valve Division of a Major Manufacturer
PROBLEM:
Customer
required a transporting device capable of presenting
the
product through an existing oven at a rate of 12" per minute.
SOLUTION:
Provide
a 180-stop rotary indexing system. The base indexes
every
five (5) seconds and utilizes an eight (8) foot diameter aluminum dial plate.
SPECIAL
CONSIDERATIONS: